Dynamic Mechanical Analyser

Dynamic Mechanical Analyser – Dynamic Material Testing by Prescott Instruments

Versatile. Powerful. Accurate.

The Dynamic Mechanical Analyser (DMA) from Prescott Instruments is a high-precision testing instrument designed for dynamic and static material testing. Featuring state-of-the-art linear motor technology, the DMA enables reliable analysis of the mechanical and viscoelastic properties of a wide range of materials.

Its robust construction, versatile testing capabilities and intuitive operation make the DMA an ideal solution for demanding applications in research, development and quality control.

Product Highlights

🟒 High Testing Force – Up to 1.75 kN static force and 2.5 kN dynamic force

🟒 High Frequency Range – Dynamic testing at frequencies of up to 100 Hz

🟒 Advanced Linear Motor Technology – Ensures precise and reliable test results

🟒 Versatile Testing Methods – Dynamic and static testing across different deformation modes

🟒 Flexible Sample Clamping – High-performance fixtures for various materials and components

🟒 Robust Design – Excellent stability, safe operation and minimal maintenance requirements

🟒 Intuitive Labline Software – Easy test setup, versatile testing modes and reliable data analysis

Applications

The Dynamic Mechanical Analyser is ideally suited for investigating the mechanical and viscoelastic properties of elastomers, rubber, plastics, polymers and technical components.

 

Technical Specifications – DynamicLine

Note: The DynamicLine DL1 and DL3 models primarily differ in their maximum static and dynamic force capacities and weight. Both models offer the same frequency range, stroke length, and test space dimensions.

Technical Specification DL1 DL3
Minimum Force 0,0001 kN 0,0001 kN
Maximum Static Force 0,7 kN 1,75 kN
Maximum Dynamic Force 1,0 kN 2,5 kN
Frequency Range 0,001 Hz bis 100 Hz 0,001 Hz bis 100 Hz
Maximum Stroke Length 88 mm 88 mm
Displacement Resolution 0,001 mm 0,001 mm
Test Space (W Γ— D Γ— H) 300 Γ— 300 Γ— 300 mm 300 Γ— 300 Γ— 300 mm
Electrical Power Supply Single-phase, 15 A Single-phase, 15 A
Weight 120 kg 150 kg
Dimensions (W Γ— D Γ— H) 800 Γ— 600 Γ— 850 mm 800 Γ— 600 Γ— 850 mm

Environmental Chamber

Technical Specifications – Environmental Chamber

Note: The Environmental Chamber enables material testing under controlled temperature conditions ranging from βˆ’60 Β°C to +180 Β°C, making it ideal for evaluating material performance at extreme temperatures.

Technical Specification Description Value
Temperature Range   βˆ’60 Β°C bis +180 Β°C
Temperature Fluctuation βˆ’60 Β°C bis +100 Β°C Β±0,3 Β°C
  +100,1 Β°C bis +180 Β°C Β±0,5 Β°C
Temperature Gradient / Spatial Temperature Variation βˆ’60 Β°C bis +100 Β°C 2,5 Β°C
  +100,1 Β°C bis +180 Β°C 4,0 Β°C
Temperature Rate of Change Heating Rate 3,2 Β°C/min
  Cooling Rate 2,1 Β°C/min
Time to Reach Extreme Temperatures Heating Time (βˆ’60 Β°C bis +180 Β°C) Within 70 minutes
  Cooling Time (+20 Β°C bis βˆ’60 Β°C) Within 70 minutes
Chamber Capacity   22,5 litres
Internal Dimensions (W Γ— H Γ— D)   300 Γ— 300 Γ— 250 mm
External Dimensions (W Γ— H Γ— D)   440 Γ— 620 Γ— 785 mm
Weight   100 kg

What Does a Dynamic Mechanical Analyser (DMA) Measure and Calculate?

Precise Analysis of Mechanical and Viscoelastic Material Properties

In Dynamic Mechanical Analysis (DMA), force and displacement are measured directly using a high-precision load cell and displacement encoder. These accurate measurements enable reliable analysis of material behaviour under various loading conditions.

By analysing the phase shift between force and displacement, the viscoelastic properties of a material can be determined. Both the elastic and viscous components of material behaviour are taken into account.

The Dynamic Mechanical Analyser from Prescott Instruments enables the measurement, calculation and evaluation of a wide range of mechanical and dynamic material properties.

Measurable and Calculated Material Properties

🟒 Stress and Strain – Determination of mechanical stress and deformation under applied loads

🟒 Young’s Modulus – Evaluation of material stiffness and elastic behaviour

🟒 Complex Dynamic Modulus – Characterisation of overall viscoelastic material behaviour

🟒 Storage Modulus – Measurement of the elastic component and the material's ability to store mechanical energy

🟒 Loss Modulus – Analysis of the viscous component and energy dissipation caused by internal friction

🟒 Storage and Loss Compliance – Evaluation of elastic and viscous deformation components

🟒 Loss Factor (Tan Delta) – Assessment of the ratio between loss and storage modulus and the material's damping characteristics

🟒 Complex Dynamic Viscosity – Analysis of viscous material behaviour under dynamic loading

🟒 Force and Displacement – Precise measurement of applied forces and resulting deformation

🟒 Linear (Hookean) Stiffness – Determination of material stiffness within the linear elastic range

🟒 Complex Stiffness – Analysis of dynamic stiffness, considering both elastic and viscous properties

🟒 Complex Stiffness Compliance – Evaluation of a material's dynamic deformation response

🟒 Damping – Investigation of a material's ability to dissipate mechanical vibration energy

🟒 Energy Storage and Losses – Analysis of stored and dissipated mechanical energy

🟒 Creep Compliance – Investigation of time-dependent deformation under constant stress

🟒 Relaxation Modulus – Determination of time-dependent stress relaxation under constant strain

🟒 Percentage Recovery – Evaluation of a material's ability to recover its original shape after deformation

 

What Materials and Testing Methods Does a Dynamic Mechanical Analyser (DMA) Support?

Versatile. Flexible. Precise.

The Dynamic Mechanical Analyser (DMA) from Prescott Instruments offers versatile testing capabilities for analysing the mechanical and viscoelastic properties of a wide range of materials.

Thanks to a comprehensive selection of high-performance clamping fixtures and sample holders, various testing methods and deformation modes can be performed, including compression, tension, shear and bending tests.

In addition, specialised grips and custom-designed testing fixtures are available to meet individual testing requirements.

The DMA accommodates a wide variety of sample geometries and materials, including rubber, plastics, elastomers, polymers and composites.

Available Testing Methods

🟒 Compression Testing – Investigation of material behaviour under compressive loading

🟒 Tension Testing – Analysis of mechanical properties and deformation behaviour under tensile loading

🟒 Shear Testing – Determination of material properties under shear stress

🟒 3-Point Bending – Evaluation of flexural stiffness and deformation behaviour under bending loads

🟒 Single Cantilever – Analysis of dynamic bending behaviour using specimens clamped at one end

🟒 Double Cantilever – Investigation of flexural properties using specimens clamped at both ends

Applications

The Dynamic Mechanical Analyser is ideally suited for testing elastomers, rubber, plastics, polymers and composite materials.

With its versatile testing methods, the DMA enables precise and reproducible material analysis for research, material development and quality control.

πŸ’¬ Interested in learning more?

We look forward to your enquiry and will be happy to provide further information, expert advice or a customised quotation.